Description
| range of product |
Harmony XAC
|
|
|---|---|---|
| product or component type |
Pendant control station
|
|
| device short name |
XACA
|
| control station type |
Double insulated
|
|
|---|---|---|
| enclosure material |
Polypropylene
|
|
| electrical circuit type |
Control circuit
|
|
| enclosure type |
Complete ready for use
|
|
| control station application |
Control of single speed hoist motor
|
|
| control station composition |
4 push-buttons
|
|
| control button type |
First push-button 1 NO raise, slow
Second push-button 1 NO lower, slow Fourth push-button 1 NO left, slow Third push-button 1 NO right, slow |
|
| product compatibility |
ZB2BE101 for each direction
|
|
| mechanical interlocking |
With mechanical interlocking between pairs
|
|
| control station colour |
Yellow
|
|
| connections – terminals |
Screw clamp terminals, 1 x 0.5…1 x 2.5 mm² without cable end
Screw clamp terminals, 1 x 0.5…2 x 1.5 mm² with cable end |
|
| standards |
EN/IEC 60947-5-1
EN/IEC 60204-32 CSA C22.2 No 14 UL 508 |
|
| product certifications |
CSA
UL GOST CCC |
|
| protective treatment |
TH
|
|
| ambient air temperature for operation |
-25…70 °C
|
|
| ambient air temperature for storage |
-40…70 °C
|
|
| vibration resistance |
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
|
|
| shock resistance |
100 gn conforming to IEC 60068-2-27
|
|
| overvoltage category |
Class II conforming to IEC 61140
|
|
| IP degree of protection |
IP65 conforming to IEC 60529
|
|
| IK degree of protection |
IK08 conforming to EN 50102
|
|
| mechanical durability |
1000000 cycles
|
|
| cable entry |
Rubber sleeve with stepped entry 8…26 mm
|
|
| contact code designation |
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A |
|
| [Ithe] conventional enclosed thermal current |
10 A
|
|
| [Ui] rated insulation voltage |
600 V (pollution degree 3)
|
|
| [Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947-1
|
|
| contact operation |
Slow-break
|
|
| maximum resistance across terminals |
25 MOhm
|
|
| operating force |
10 N push-button
|
|
| short-circuit protection |
10 A fuse protection by cartridge fuse type gG
|
|
| rated operational power in W |
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
|
| terminals description ISO n°1 |
(13-14)NO
|
|
| terminal identifier |
(13-14)NO
(11-12)NC |
|
| net weight |
0.625 kg
|