Descripción
range of product |
Harmony XB4
Harmony XB5 |
|
---|---|---|
product or component type |
Contact block
|
|
device short name |
ZBE
|
|
sale per indivisible quantity |
5
|
|
IP degree of protection |
IP20 conforming to IEC 60529
|
|
contacts type and composition |
1 NC
|
|
contact operation |
Slow-break
|
|
contact block type |
Single
|
|
contacts usage |
Standard contacts
|
|
connections – terminals |
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1 |
net weight |
0.011 kg
|
|
---|---|---|
positive opening |
With conforming to EN/IEC 60947-5-1 appendix K
|
|
operating travel |
1.5 mm (NC changing electrical state)
4.3 mm (total travel) |
|
operating force |
2 N NC changing electrical state
|
|
mechanical durability |
10000000 cycles
|
|
tightening torque |
0.8…1.2 N.m conforming to EN 60947-1
|
|
shape of screw head |
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver |
|
contacts material |
Silver alloy (Ag/Ni)
|
|
short-circuit protection |
10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
|
|
[Ith] conventional free air thermal current |
10 A conforming to EN/IEC 60947-5-1
|
|
[Ui] rated insulation voltage |
600 V (pollution degree 3) conforming to EN 60947-1
|
|
[Uimp] rated impulse withstand voltage |
EN 60947-1 6 kV
|
|
[Ie] rated operational current |
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
|
electrical durability |
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
|
electrical reliability |
Λ < 10exp(-7), 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8), 5 mA in clean environment conforming to EN/IEC 60947-5-4 |
|
mounting of block |
Front mounting
|
|
condition of use |
Mounting on push-button collar
|
|
electrical composition code |
C1 (quantity <= 9)
C2 (quantity <= 7) C3 (quantity <= 6) C4 (quantity <= 4) C5 (quantity <= 5) C6 (quantity <= 3) C7 (quantity <= 4) C8 (quantity <= 2) C9 (quantity <= 3) C12 (quantity <= 6) M1 (quantity <= 6) M2 (quantity <= 4) M3 (quantity <= 4) M5 (quantity <= 2) M6 (quantity <= 2) M7 (quantity <= 6) M8 (quantity <= 4) M9 (quantity <= 2) SF1 (quantity <= 3) SF2 (quantity <= 2) MF1 (quantity <= 2) MF2 (quantity <= 2) C10 (quantity <= 2) M4 (quantity <= 2) C13 (quantity <= 1) |
|
compatibility code |
ZBE
|