Descripción
range of product |
OsiSense XC
|
|
---|---|---|
series name |
Standard format
|
|
product or component type |
Limit switch body
|
|
device short name |
ZCKM
|
|
body type |
Fixed
|
|
product compatibility |
XCKM
|
|
associated head |
ZCKD08
ZCKD06 ZCKD219 ZCKD41 ZCKD02 ZCKD81 ZCKD05 ZCKD109 ZCKD16 ZCKD23 ZCKD91 ZCKD029 ZCKD17 ZCKD59 ZCKD15 ZCKD21 ZCKD239 ZCKD10 |
|
body material |
Metal
|
|
cable entry |
3 entries tapped for Pg 11 cable gland
|
|
number of poles |
2
|
|
contacts type and composition |
1 NC + 1 NO
|
|
contact operation |
Snap action
|
|
number of steps |
1 1 position
|
|
contacts material |
Silver plated contacts
|
local display |
Without
|
|
---|---|---|
electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.34…2 x 1.5 mm²
|
|
positive opening |
With
|
|
minimum actuation speed |
0.01 m/min
|
|
[Ie] rated operational current |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
|
[Ithe] conventional enclosed thermal current |
10 A
|
|
[Ui] rated insulation voltage |
500 V (pollution degree 3) conforming to IEC 60947-1 for contact block
300 V conforming to CSA C22.2 No 14 for contact block 300 V conforming to UL 508 for contact block |
|
maximum resistance across terminals |
0.25 mOhm conforming to IEC 60255-7 category 3
|
|
[Uimp] rated impulse withstand voltage |
IEC 60664 6 kV
IEC 60947-1 6 kV |
|
short-circuit protection |
10 A cartridge fuse, type gG
|
|
electrical durability |
5000000 cycles, DC-13 120 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 13 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13 48 V, 9 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
|
width |
64 mm
|
|
height |
64 mm
|
|
depth |
30 mm
|
|
net weight |
0.21 kg
|
|
terminals description ISO n°1 |
(21-22)NC
(13-14)NO |